IR Resolution |
640*480 |
Standard lense |
29°*22° |
Minimum focus distance |
0.1m |
Macro Lenses |
M20 &M50 (Image Pixel Size: 20μm & 50μm) |
Thermal Sensitivity(NETD) |
30mk@30° C(86 ℉ ) |
Temperature Measurement Range |
-20℃ ~120℃, (-4 ℉ ~248 ℉ ), 0℃ ~650℃ (32 ℉ ~1202 ℉ ) |
User-definable Markers |
5 spot markers; 10 (rectangle or circle); 10 measurement lines |
Accuracy |
± 2℃ (3.6 ℉ ) or ± 2 %, whichever is greater (ambient temp at 25℃ (77 ℉ )) |
Support Radiometric Stream |
25Hz radiometric stream |
Palettes |
9 standard palettes and 9 inverted palettes |
Focus Type |
Manual Focus |
Enclosure Rating |
IP40 |
Weight |
490g(without lens or base) |